Precision Ultrasonic Range
Sensing
Range-finding at a fraction of the
cost of other precision rangefinders
Reading-to-reading stability of
1-mm at 1-meter is typical
Accuracy is factory-matched at
1-meter to 0.1% providing a typical
large target accuracy of 1% or better
for most voltages and uses1
Calibrated acoustic detection zones
allows users to choose the part
number with the detection zone that
matches their specific application
Compensation provided for target
size variation and operating voltage
range
Internal temperature compensation is
standard
Optional external temperature
compensation


Very Low Power
Requirements
Wide, low supply voltage
requirements eases battery powered
design
Low current draw reduces current
drain for battery operation
Fast first reading after power-up
eases battery requirements


Easy to use Component
Module
Stable and reliable range readings
and excellent noise rejection make
the sensor easy to use for most users
Easy to use interface with distance
provided in a variety of outputs
Target size compensation provides
greater consistency and accuracy
when switching targets
Sensor automatically handles
acoustic noise1,2
Sensor ignores other acoustic noise
sources
Small and easy to mount
Calibrated sensor eliminates most
sensor to sensor variations
Very low power ranger, excellent for
multiple sensor or battery based
systems

Range Outputs
Pulse width, (1uS/mm)
Analog Voltage, (5mm resolution)
Serial, (RS232 or TTL, where TTL
format by solderable jumper or
volume orders available as no-cost
factory installed jumper)


General Characteristics
Low cost ultrasonic rangefinder
Sensor dead zone virtually gone,
Size less than 1 cubic inch with easy
mounting
Object proximity detection from
1-mm to 5-meters
Resolution of 1-mm
Distance sensor from 30-cm to
5-meters
Excellent2 Mean Time Between
Failure (MTBF)
Triggered operation yields a
real-time
100mS measurement cycle
Free run operation uses a 2Hz filter,
with 100mS measurement and
output cycle
Operating temperature range
from -15°C to +65°C, provided
proper frost prevention is employed
Operating voltage from 2.5V to 5.5V
Nominal current draw of 2.5mA at
3.3V, and 3.1mA at 5V


Applications & Uses
Bin level measurement
Proximity zone detection
People detection
Robots ranging sensor
Autonomous navigation Distance
measuring
Long range object detection
Environments with acoustic and
electrical noise
Height monitors
Auto sizing